Slickdeals is community-supported.  We may get paid by brands or deals, including promoted items.
Sorry, this deal has expired. Get notified of deals like this in the future. Add Deal Alert for this Item
Forum Thread

Klein Advanced Circuit Tracer Kit ET450 with free 14-in-1 Adjustable Screwdriver (Acme Tools) $186.48

$186.49
+6 Deal Score
6,700 Views
Klein Advanced Circuit Tracer Kit ET450
&
Free Promotional 14-in-1 Adjustable Screwdriver 32303F

$20 OFF Coupon Code: DADSDAY20
Shipping: $6.49
Total: $186.49 + tax

https://www.acmetools.com/advance...93380.html
Good Deal?
If you purchase something through a post on our site, Slickdeals may get a small share of the sale.
Deal
Score
+6
6,700 Views

11 Comments

Your comment cannot be blank.

Sign up for a Slickdeals account to remove this ad.

Joined Jun 2014
L10: Grand Master
> bubble2 6,792 Posts
ToolDeals
06-11-2022 at 07:19 AM.
06-11-2022 at 07:19 AM.
.
Made in China, the price is reasonable for a thumb up.

================

Edit for... There is a lot of misinformation being posted. This kit is for "for energized and non-energized breakers, fuses, and wires." Besides defining breaker, live or dead circuits, continuity, etc., you adjust the sensitivity for finding and tracing hidden AC, DC and cable circuits behind walls, buried, etc. If you don't take the time to research how to use it with at least some intimacy with electric, then of course it is just a brick.

Here is an introduction video [youtube.com] and of course, many others.

You can buy individual components that many of us have a box of, but the cost is in the sensitivity for various diagnostics. If you are just trying to find which breaker is for which circuit, this is an overkill.
>
1
Like
Funny
>
Helpful
Not helpful
Reply
Last edited by ToolDeals June 12, 2022 at 06:00 AM.
Joined Jun 2021
L2: Beginner
> bubble2 86 Posts
26 Reputation
DougEFresh83
06-11-2022 at 07:23 AM.
06-11-2022 at 07:23 AM.
Note to those buying. Unless you are using these in a home with a single breaker box they are completely useless. I've used this in houses with sub panels and generators, and this will not point you in the direction of the correct breaker.
1
1
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Aug 2013
L7: Teacher
> bubble2 2,875 Posts
6,273 Reputation
Pro
bargainhunterforever
06-11-2022 at 08:12 AM.
06-11-2022 at 08:12 AM.
Quote from DougEFresh83 :
Note to those buying. Unless you are using these in a home with a single breaker box they are completely useless. I've used this in houses with sub panels and generators, and this will not point you in the direction of the correct breaker.
Thanks for the heads up Doug! Is there a product that will work with sub panels and generator connectors that you have found useful? Thanks again for calling this out.
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Jun 2021
L2: Beginner
> bubble2 86 Posts
26 Reputation
DougEFresh83
06-11-2022 at 08:24 AM.
06-11-2022 at 08:24 AM.
Quote from bargainhunterforever :
Thanks for the heads up Doug! Is there a product that will work with sub panels and generator connectors that you have found useful? Thanks again for calling this out.

I've yet to find a single product that works with sub panels to be honest.

The best method I've seen is using a noise maker like this and hit every breaker until it stops screaming.
https://a.co/fnSITWH
1
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Aug 2013
L7: Teacher
> bubble2 2,875 Posts
6,273 Reputation
Pro
bargainhunterforever
06-11-2022 at 09:53 AM.
06-11-2022 at 09:53 AM.
Quote from DougEFresh83 :
I've yet to find a single product that works with sub panels to be honest.

The best method I've seen is using a noise maker like this and hit every breaker until it stops screaming.
https://a.co/fnSITWH
Thanks.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Jun 2021
L2: Beginner
> bubble2 86 Posts
26 Reputation
DougEFresh83
06-11-2022 at 10:24 AM.
06-11-2022 at 10:24 AM.
I'll add the description does say "for tracing non-energized breakers" which could be why I've never had luck with these circuit tracers.
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Jan 2005
L3: Novice
> bubble2 145 Posts
120 Reputation
T-SHIZZLE
06-11-2022 at 12:30 PM.
06-11-2022 at 12:30 PM.
for a live circuit you can also use a loud radio instead of an outlet noisemaker (which can be annoying). Or my dad would sometimes run a long extension cord with a light bulb and run it all the way back to the breaker and would immediately be able to see the light go on and off. That way the work is a lot quieter.
1
Like
Funny
>
Helpful
Not helpful
Reply

Sign up for a Slickdeals account to remove this ad.

Joined Jun 2014
L10: Grand Master
> bubble2 6,792 Posts
ToolDeals
06-12-2022 at 08:04 AM.
06-12-2022 at 08:04 AM.
Quote from T-SHIZZLE :
for a live circuit you can also use a loud radio instead of an outlet noisemaker (which can be annoying). Or my dad would sometimes run a long extension cord with a light bulb and run it all the way back to the breaker and would immediately be able to see the light go on and off. That way the work is a lot quieter.
.
That is true. Although easier with two people and today with cell phones, but when alone, we used to lay a drill on the floor that could be heard far away and start flipping breakers. But a loud radio would be fine.

If finding a breaker for a circuit is all that one wants to do, as in the edited first post, the OP is an overkill. There are plenty of cheap continuity checkers with tone, but still check the circuit to make sure you flipped the correct breaker and that outlet is not somehow back fed from a neutral side wire, screwed up 3 or 4 way wiring, switches, etc.

Nothing like working on a presumed dead circuit and someone flips a light switch that back feeds and becomes hot... lol .... If any doubts, use the NCV (Non Contact Voltage) function laying close that will help if you are quick. 110v is not typically the end of the world, but it will get your attention; especially on tiled slab (concrete) floors.

Note: About the time you think you have experienced everything, something new shows up. If I cannot figure a short very quickly, I have started going outside and checking for ground voltage that if present, is leaking from somewhere and start back tracking. Many people have died from leaking ground voltage and swimming pools (it does not take much) that could very well be coming from the grid system a block away (that copper ground wire from transformer that goes down the pole and coiled underneath the base), your neighbor that has the ground screw connecting neutral in breaker box, or you. It takes just a moment to check.
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Oct 2004
L4: Apprentice
> bubble2 432 Posts
80 Reputation
wrangler1114
06-13-2022 at 01:22 PM.
06-13-2022 at 01:22 PM.
I can't get the coupon to work.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Dec 2021
L1: Learner
> bubble2 18 Posts
10 Reputation
ScarletCircle978
08-09-2022 at 04:12 PM.
08-09-2022 at 04:12 PM.
Quote from bargainhunterforever :
Thanks for the heads up Doug! Is there a product that will work with sub panels and generator connectors that you have found useful? Thanks again for calling this out.

Doug must not be using it right. I have no problem using this on multiple panel services. There is false readings, it's the nature of the device, but you can tell. Was looking through past klein deals, saw this.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Aug 2013
L7: Teacher
> bubble2 2,875 Posts
6,273 Reputation
Pro
bargainhunterforever
08-09-2022 at 06:52 PM.
08-09-2022 at 06:52 PM.
Quote from ScarletCircle978 :
Doug must not be using it right. I have no problem using this on multiple panel services. There is false readings, it's the nature of the device, but you can tell. Was looking through past klein deals, saw this.
Thanks.
1
Like
Funny
>
Helpful
Not helpful